700
series
★ ★ ★
> Maximum flexibility
> Dual electrode
> Multiple pumps and detectors
> Pulse-free pump
++++++++
Expandability is the keyword for the 700 Series.
Extra pumps and detectors can be added as necessary. The standard configuration includes the ECD-700 detector equipped with one amperometric cell, the EP-700 pump unit with one microflow pump installed, and the ATC-700 temperature control unit, The pump unit also has a two channel solvent degasser built in.
Electrochemical Detector
ECD-700
ECD-700
【Electrochemical Detector】
feature
> Add an ECD to any HPLC system
> Two cells per detector possible
> Amperometric or coulometric cells
> Dual electrode
Standard Features
-
Superior sensitivity and stability of Eicom’s electrochemical detector technology.
-
Easy to maintain.
-
Maximized up-time.
-
One amperometric electrochemical detector cell with a constant voltage configuration using the same type of flow cell as the HTEC-510.
-
Available materials of working electrode; graphite, pure graphite, glassy carbon, platinum, gold, silver.
-
Easy access to the working electrode.
ECD-700
Electrochemical Cell
Amperometric with 3 electrode DC potentiostat (standard): Space for optional
second cell (optional)
Coulometric or amperometric
Working Electrode
Graphite composite(standard),glassy carbon, pure graphite, platinum, gold,
silver
Optional Dual Electrode
Glassy carbon, graphite composite (both use a shared reference)
Reference Electrode
Ag/AgCl
Counter Electrode
316 stainless steel
Applied Voltage Range
-2000mV to +2000mV, 1mV increments
Auto Zero Function
Between -1000 nA and + 1000 nA: triggered by external input
★
★
HPLC Pump Unit
EP-700
EP-700
【HPLC Pump】
> Pulse quenching by computer control
> Two channel degasser included
> No pulse damper necessary
> Gradient control built in
EP-700
Pressure Limit
20Mpa
Micro Flow Pump
100μL/min, 1μL increment, 4μL/stroke
High Flow Pump
0.5 - 3.0 mL/min, 0.01 mL increments, 32μL/ stroke
Wetted Surfaces
PEEK, Sapphire, Ruby PCTFE
Special Features
Gradient control built in, input signal for star / stop
Built-in Degasser
2channels: 300μL volume/ ea, up to 3.0 mL/min
Temperature Controller
ATC-700
ATC-700
【Temperature】
ATC-700
Temperature control provides the most stable retention times and detector signals.The ATC-700 performs this function even at room temperature due to its ability to both heat and cool.
Temperature Range
15-55℃, 1℃ increments, 20-45℃ (Recommended range)
size: 400 (w) x 400 (d) x 145 (h) cm。
weight 10 kg。
AC 100-240 V, 50/60 Hz, 210 VA